What if you could have a PSG system that helped you meet your ever changing business and clinical needs? Pair the LDx base station with either the LDxS or LDxN head box to have a full-featured, easy-to-understand system that allows staff to focus more on patients and less on equipment.The LDxS is the perfect front-line head box for most sleep center needs. Place the LDxN into use when you need to step up from the 19 EEG inputs on the LDxS to a full 32 EEG inputs.The LDx base station works with either head box,so it’s easy to have the right capability where, and when, you need it.
Integrated RIP driver reduces connections
Set-up patients faster and easier. The integrated RIP driver, dedicated differential pressure transducer, and "keyhole" inputs reduce the number of connections during hook-up.
Continuous impedance recording for quality control
Patent-pending chin EMG technology for advanced monitoring
Monitor all three chin EMG inputs and select the best pair in real-time using our patent-pending chin EMG technology.
Two configurations for diagnostic flexiblity
The Alice 6 LDx base station works with two head boxes so it’s easy to have the right capability where, and when, you need it. The LDxS head box offers 19 EEG inputs and the LDxN head box offers 32 EEG inputs.
FEATURES |
• Integrated RIP driver, dedicated differential pressure transducer, and “keyhole” inputs (reduces the number of connections during hook up)
• Patent-pending chin EMG technology that monitors all three chin EMG inputs and selects the best pair in real-time
• 7 ECG channels (3 physical and 4 derived)
• Continuous impedance recording for quality control
• Up to 500Hz recording
• Meets or exceeds AASM standards
SPECIFICATIONS |
Internal memory/data storage | 60 GB hard drive |
Total channels | 55 channels |
Video | networked |
EEG | 19 inputs |
Audio | integrated with video + VOIP intercom |
Dedicated EMG | 5 channels |
Max sampling rate | 2000 Hz |
Chin EMG | 3 inputs |
Automatic chin EMG referencing | Yes |
EOG | 2 channels |
ECG | 7 (3 physical and 4 derived) channels |
"V" ECG input | Yes |
Pressure transducer | Dedicated differential w/snore |
Flow | (thermal) Yes |
Snore | Yes |
Body position | 1 |
Actimeter inputs | 2 |
light sensor | optional accessory |
effort (chest/abdominal) | zRIP DuraBelt Integrated RIP driver |
Aux inputs/DC inputs | 8 |
Battery | No |
Signal resolution/bit | 16 bit |
Pulse transit time | Yes |
Max storage rate | 500 Hz |
Electrode interface | Intuitive image |
Digital Philips Respironics therapy device interface | Yes |
Bedside display | No |
Connectivity | capable (wired ethernet) |
Pulse oximetry | Nonin |
INCLUDES:
- Base station
- Auto-switching power supply
- AC power cord, patient cable
- Head box shoulder strap
- User's guide
PM IS CURRENT
JUST TAKEN OUT OF SERVICE